7212291-01 (06/14) EcoBlue Heat 11
Technical Specifications 3
3 Technical Specifications
3.1 Technical Data
NOTE: All data in this section are nominal
values and subject to normal production
tolerances.
Outercase Dimensions
Overall Height Inc Flue Elbow - 790mm
Casing Height - 625mm
Casing Width - 370mm
Casing Depth - 280mm
Electrical Supply 230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Power Consumption
12 model 17W
15 model 20W
18 model 23W
21 model 25W
24 model 33W
External Fuse Rating 3A
Clearances
Both Sides 5mm Min
Above Casing (Top Flue) 190mm Min
Above Casing (Rear Flue) 35mm Min
Below Casing (in Cupboard) 35mm Min
Below Casing 120mm Min
Front (For Servicing) 800mm Min
Front (In Operation) 5mm Min
Flow Temperature (adjustable)
30° C to 80° C (± 5° C)
Ventilation of Compartment
Where the boiler is installed in a cupboard
or compartment, no air vents are required
for cooling purposes providing that the
minimum dimensions above are maintained.